It is recommended to perform a factory reset on a fridge before assessing for fault, as altered fridge settings outside the scope of what is covered in the manual may lead to a variety of issues.
How to perform a factory reset for plastic-case portable fridges (except GH2100/GH2102/GH2106):
- On standby (plugged in but power off), press the set key until the display shows E1.
- Press + and – simultaneously until the display shows -188 (or 888 or 000)
- Press the power button to restart
See this video on how to do this: https://bmc.worldmanager.com/go/WNPWs1
If your fridge has a divider, make sure the divider is inserted, with the small plastic plug located at the bottom of the fridge, as this contains a magnet that controls how the zones work.
The fridge should then be left on for a minimum of 5 minutes to allow the compressor time to start up before troubleshooting can begin.
How to perform a factory reset for the Stainless Steel portable fridges (e.g. GH1646):
- Press the power button to turn off the unit.
- Press + Hold the 'Compressor Speed' button until 888 appears on the temp displays.
- Press the power button to finalise.
- All temps and settings will be set back to default.
Brass Monkey Fridge diagnostic error codes
Error | Fault | Common Fix |
F1 | Battery protection mode | There are 3 levels of battery protection. The default is H(igh) and offers the best protection, however, may cause issues when running from a battery or vehicle using a long lead. To adjust the protection mode, press Set for 3 seconds, screen flashes H. If error code F1, set to M(edium) or L(ow). |
F2 | Fan overload protection mode | Switch it off for 30 minutes to allow the system to cool down. Please ensure there is adequate ventilation around the fan vents. |
F3 | Compressor frequent start protection mode | Switch it off for 30 minutes to allow the compressor to cool down. Ensure the fridge is stored out of direct sunlight in a cool area. Turn it on so the compressor runs. Tilt it left and right briefly to redistribute the working fluids. Then set it level. Make sure the vents are not covered by nearby obstructions and air can flow into and out of the vents. |
F4 | Compressor is overloaded mode | |
F5 | Compressor high temperature protection mode | |
F6 | Controller detection error | Switch off and then on again after a minute. If issue persists a connection may be loose due to vibration or a manufacturing issue. |
F7 | Temperature sensor error | faulty sensor terminal, refer instructions. |
F8 |
If you are still having issues & have performed a factory reset & are not seeing an error code, please contact your local Jaycar store for further support.
Comments
0 comments
Article is closed for comments.